{"title":"Siemens LME7 Controls","description":"\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eWhat Does The LME7 Controller Do?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe LME7 burner control is ideally suited for use in industrial thermal process applications.  The LME7 is extremely flexible and includes the following features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eAccepts standard UV, self-check UV, or self-check IR scanners and\/or flame rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIntegral LED display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eProgrammable purge times and safety times\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eProgrammable actuator positions for purge, ignition, and low fire\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eAdjustable time overlap of spark ignition and pilot valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eAdjustable time overlap of the pilot and main gas valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eProof-of-closure (POC) switch monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eModbus RTU or BACnet MS\/TP communication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional gas valve proving function\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003ePassword-protected access to OEM parameters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIntegrated actuator control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIntegrated PWM blower control\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin: 10px 10px 10px 10px; float: none;\" alt=\"Siemens LME7 Burner Controls System\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/Siemens_LME7_480x480.png?v=1659342919\"\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eBase Unit\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eYou will require one of the LME7 base units:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e LME71.0001A1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame safeguard, without actuator control, without self-check scanner capability, 110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e LME73.0001A1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eFlame safeguard, with actuator control, without self-check scanner capability, 110V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e LME75.0001A1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eFlame safeguard, with actuator control, with self-check scanner capability, 110V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eProgram Module \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eChoose one of the following PME7 program modules.  The program module contains the program sequence used to operate the burner. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e Model\u003c\/td\u003e\n\u003ctd\u003eBase\u003cbr\u003eUnit\u003c\/td\u003e\n\u003ctd\u003eActuator \u003cbr\u003eControl \u003cbr\u003eCan Be \u003cbr\u003eDisabled\u003c\/td\u003e\n\u003ctd\u003eControl \u003cbr\u003ePWM \u003cbr\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eFlame \u003cbr\u003eRod\u003c\/td\u003e\n\u003ctd\u003eNon \u003cbr\u003eSelf-Check \u003cbr\u003eUV Scanner\u003c\/td\u003e\n\u003ctd\u003eSelf Checking\u003cbr\u003eUV or \u003cbr\u003eIR Scanner\u003c\/td\u003e\n\u003ctd\u003eValve \u003cbr\u003eProving\u003c\/td\u003e\n\u003ctd\u003ePurge\u003c\/td\u003e\n\u003ctd\u003eInd.\u003cbr\u003eIgnition Position\u003c\/td\u003e\n\u003ctd\u003eAnalog\u003cbr\u003e Input for\u003cbr\u003e Fire Rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME71.111A1\u003c\/td\u003e\n\u003ctd\u003eLME71.000A1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME71.112A1 \u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLME71.000A1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME71.901A1\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLME71.000A1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME73.811A1 \u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLME73.000A1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e✅\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME73.812A1 \u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLME73.000A1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME73.840A1 \u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLME73.000A1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME75.811A1 \u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLME75.000A1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003ePME75.812A1 \u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLME75.000A1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePlug Set\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe terminal plug set for the LME7 is sold separately.  Each LME7 needs one plug set. \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e AGG3.710\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug set containing all terminals for an LME7 system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRemote Display (Optional)\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eEach LME7 can be equipped with a remote display that provides additional status information not shown by the integral LED display on the LME7.  Either the remote display or the ACS410 software are required to change parameter settings on the LME7.\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e ALZ23.00A9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBacklit remote display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRemote Display Cable (Optional) \u003cbr\u003e\n\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e TDCCOMBO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-made 7-foot cable and adapter for connecting the AZL23 display to the LME7 base unit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInterface Modules and Accessories\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eA separate interface module is required for Modbus or BACnet MS\/TP communication with the LME7. \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOCI417.10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus and BACnet MS\/TP interface module  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDC207\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-foot cable to connect OCI417.10 to LME7 base unit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Siemens LME7 is designed to be used with SQM4 and SQM5 actuators. It can be used with QRA4, QRA75 and QRI2 Flame Scanners.\u003c\/p\u003e\n\u003cp\u003eIf you would like further assistance in designing your LME7 based system, please contact us and we will be more than happy to help.\u003c\/p\u003e","products":[{"product_id":"siemens-pme73-840a1-program-module-110v","title":"Siemens PME73.840A1 Programming Module 110v","description":"Professional PME73 series program module designed for LME73.000A1 flame safeguard controllers. Floating\/bumping actuator control with valve proving, actuator can be disabled. Key features include: Floating\/bumping actuator control, Valve proving, Actuator disable capability, Position proportional. Provides actuator control, valve proving. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.840A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Floating\/bumping actuator control with valve proving, actuator can be disabled\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eFloating\/bumping actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eActuator disable capability\u003c\/li\u003e\n \u003cli\u003ePosition proportional\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME73.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43773982114046,"sku":"SPA212","price":131.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_747efd89-dca1-4e0a-8117-40637627feca.png?v=1753853800"},{"product_id":"siemens-pme73-840a2-program-module-230v","title":"Siemens PME73.840A2 Programming Module 230v","description":"Professional PME73 series program module designed for LME73.000A2 flame safeguard controllers. Floating\/bumping actuator control with valve proving, actuator can be disabled. Key features include: Floating\/bumping actuator control, Valve proving, Actuator disable capability, Position proportional. Provides actuator control, valve proving. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.840A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Floating\/bumping actuator control with valve proving, actuator can be disabled\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eFloating\/bumping actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eActuator disable capability\u003c\/li\u003e\n \u003cli\u003ePosition proportional\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME73.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43773982179582,"sku":"SPA213","price":131.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_747efd89-dca1-4e0a-8117-40637627feca.png?v=1753853800"},{"product_id":"siemens-pme73-830a1-programming-module","title":"Siemens PME73.830A1 Programming Module 110v","description":"Professional PME73 series program module designed for LME73.000A1 flame safeguard controllers. Advanced actuator control with enhanced safety features. Key features include: Advanced actuator control, Enhanced safety, Multiple operating modes. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.830A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced actuator control with enhanced safety features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced actuator control\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003cli\u003eMultiple operating modes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME73.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774025859326,"sku":"SPA272","price":113.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_747efd89-dca1-4e0a-8117-40637627feca.png?v=1753853800"},{"product_id":"siemens-azl23-00a9-display-and-operating-unit-for-lmv2-lmv3-lme-1","title":"Siemens AZL23.00A9 Display and Operating Unit for LMV2\/LMV3\/LME","description":"\u003ch3\u003eSiemens Display and Operating Unit for LMV3 Controllers\u003c\/h3\u003e\n \u003cp\u003e\u003cstrong\u003eSiemens Part Number: BPZ:AZL23.00A9\u003c\/strong\u003e\u003c\/p\u003e\n \u003ch4\u003eOverview\u003c\/h4\u003e\n \u003cp\u003eThe Siemens AZL23.00A9 is an advanced display and operating unit meticulously engineered for seamless integration with Siemens LFS1 flame safeguards, LME39\/LMO39 burner controls, and LMV2\/LMV3 burner management systems. Designed for both on-burner and near-burner control panel installations, this unit is your go-to solution for sophisticated burner function management.\u003c\/p\u003e\n \u003ch4\u003eKey Features\u003c\/h4\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eAdvanced Display \u0026amp; Operation\u003c\/strong\u003e: Enables real-time monitoring and parameterisation of safety-critical and non-safety-related burner functions.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eData \u0026amp; Diagnostics\u003c\/strong\u003e: Query and display essential plant data and fault codes for comprehensive system oversight.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eBCI Interface\u003c\/strong\u003e: Ensures robust communication with flame safeguards and burner controls via the BCI interface.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch4\u003eSpecifications\u003c\/h4\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eIP54 Rated\u003c\/strong\u003e: Guarantees a high level of protection against dust and water ingress when mounted.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eModern, Recyclable Housing\u003c\/strong\u003e: Crafted from flame-resistant, recyclable plastic for enhanced safety and sustainability.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003e8-Digit LCD with Bars\u003c\/strong\u003e: Provides a clear, backlit display for easy monitoring (support dependent on the respective flame safeguard\/burner control).\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eMulti-Functionality\u003c\/strong\u003e: Equipped with 5 multifunction buttons with reset capabilities for streamlined operation.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e: Prepared for extra fault indication via LED and offers backup\/restore functions with specific flame safeguards\/burner controls (available upon request).\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.174 Kg, making it a lightweight yet robust unit.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eStandard Lead Time\u003c\/strong\u003e: Ex-works in 15 days, ensuring quick delivery.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Manufactured in Germany, adhering to high-quality standards.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003cli\u003e\n \u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e: Conforms to RoHS as of 24\/04\/15 and includes substances like Lead titanium zirconium oxide in concentrations higher than 0.1% w\/w, which are assumed to pose no risk when used as intended.\u003c\/p\u003e\n \u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch4\u003eCompatibility \u0026amp; Integration\u003c\/h4\u003e\n \u003cp\u003eThe AZL23.00A9 unit's functionality and operating philosophy are tailored based on the type of flame safeguard and burner control deployed, ensuring a harmonious and efficient system.\u003c\/p\u003e\n \u003cul\u003e\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774228889854,"sku":"SPA328","price":103.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-AZL2300A9-Operator-Display-For-LMV3-Control-Box-Display-Unit_046b3fe5-24c9-4ff1-b946-59d8e760dd10.webp?v=1753853672"},{"product_id":"siemens-lme71-000a1-110v-burner-control-box-1","title":"Siemens LME71.000A1 110v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME71.000A1 Burner Control Box 110V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME71.000A1 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME71.000A1 Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME71 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003e\u003c\/h3\u003e\n \u003ch3\u003eFeatures\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003ePrepurge Time: 9s\u003c\/li\u003e\n \u003cli\u003eSafety Time: 5s\u003c\/li\u003e\n \u003cli\u003ePre-ignition time: 2s\u003c\/li\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 110VAC\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg width=\"100%\" alt=\"LME71.000A1 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n \u003ctable class=\"table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Box\u003c\/th\u003e\n \u003cth\u003eHeight\u003c\/th\u003e\n \u003cth\u003eWidth\u003c\/th\u003e\n \u003cth\u003eDepth\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eLME71.000A1 230V\u003c\/td\u003e\n \u003ctd\u003e180mm\u003c\/td\u003e\n \u003ctd\u003e120mm\u003c\/td\u003e\n \u003ctd\u003e52.6mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774259265790,"sku":"SPA629","price":189.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-LME71000A1-110V-Burner-Control-Box-Control-Box_541489ad-cf91-45fa-a8f1-20551111d7cc.webp?v=1753853507"},{"product_id":"siemens-lme71-000a2-230v-burner-control-box","title":"Siemens LME71.000A2 230v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME71.000A2 Burner Control Box 230V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME71.000A2 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME71.000A2 Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME71 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003ewFeatures\u003c\/span\u003e\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003cul\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\" alt=\"LME71.000A1 Dimensions\" width=\"100%\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774259331326,"sku":"SPA630","price":178.54,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-LME71000A2-230V-Burner-Control-Box-Control-Box_e1221e25-980d-4c40-ba92-24ce7e65c40b.webp?v=1753853507"},{"product_id":"siemens-lme72-000a2-230v-burner-control-box","title":"Siemens LME72.000A2 230v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME72.000A2 Burner Control Box 230V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME72.000A2 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME72.000A2 Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME72 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eFeatures\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eOutput actuator control\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg width=\"100%\" alt=\"LME72.000A2 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n \u003ctable class=\"table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Box\u003c\/th\u003e\n \u003cth\u003eHeight\u003c\/th\u003e\n \u003cth\u003eWidth\u003c\/th\u003e\n \u003cth\u003eDepth\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eLME72.000A2 230V\u003c\/td\u003e\n \u003ctd\u003e180mm\u003c\/td\u003e\n \u003ctd\u003e120mm\u003c\/td\u003e\n \u003ctd\u003e52.6mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774259364094,"sku":"SPA631","price":213.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-LME72000A2-230V-Burner-Control-Box-Control-Box_c6bdc95f-032c-469e-a951-5050a793bcbd.webp?v=1753853506"},{"product_id":"siemens-lme73-000a2-230v-burner-control-box","title":"Siemens LME73.000A2 230v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME73.000A2 Burner Control Box 230V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME73.000A2 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME73.000A2 Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME73 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eFeatures\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eOutput actuator control\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n \u003cli\u003eInput feedback for actuator with a potentiometer\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\" alt=\"LME72.000A2 Dimensions\" width=\"100%\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n \u003ctable class=\"table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Box\u003c\/th\u003e\n \u003cth\u003eHeight\u003c\/th\u003e\n \u003cth\u003eWidth\u003c\/th\u003e\n \u003cth\u003eDepth\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eLME73.000A2 230V\u003c\/td\u003e\n \u003ctd\u003e180mm\u003c\/td\u003e\n \u003ctd\u003e120mm\u003c\/td\u003e\n \u003ctd\u003e52.6mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774259396862,"sku":"SPA632","price":225.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-LME73000A2-230V-Burner-Control-Box-Control-Box_29eee385-b177-43c7-943c-132d27901a96.webp?v=1753853505"},{"product_id":"siemens-lme73-000a1-110v-burner-control-box","title":"Siemens LME73.000A1 110v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME73.000A1 Burner Control Box 110V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME73.000A1 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME73.000A Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME73 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eFeatures\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eOutput actuator control\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 110VAC\u003c\/li\u003e\n \u003cli\u003eInput feedback for actuator with a potentiometer\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\" alt=\"LME73.000A1 Dimensions\" width=\"100%\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n \u003ctable class=\"table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Box\u003c\/th\u003e\n \u003cth\u003eHeight\u003c\/th\u003e\n \u003cth\u003eWidth\u003c\/th\u003e\n \u003cth\u003eDepth\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eLME73.000A1 110V\u003c\/td\u003e\n \u003ctd\u003e180mm\u003c\/td\u003e\n \u003ctd\u003e120mm\u003c\/td\u003e\n \u003ctd\u003e52.6mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774259462398,"sku":"SPA633","price":236.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-LME73000A1-110V-Burner-Control-Box-Control-Box_32aaaf32-18e3-464e-85b9-b41101612214.webp?v=1753853504"},{"product_id":"siemens-lme75-000a2-230v-burner-control-box","title":"Siemens LME75.000A2 230v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME75.000A2 Burner Control Box 230V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control L\u003c\/span\u003eME75.000A2 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME75.000A2 Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME75 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003cbr\u003e\n \u003cp\u003eThis control box has a designed lifetime* of 250,000 burner startup cycles which, under normal operating conditions in heating mode, correspond to approx. 10 years of usage (starting from the production date given on the type field).\u003c\/p\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eFeatures\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eOutput actuator control\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n \u003cli\u003eInput feedback for actuator with a potentiometer\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\" alt=\"LME75.000A2 Dimensions\" width=\"100%\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n \u003ctable class=\"table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Box\u003c\/th\u003e\n \u003cth\u003eHeight\u003c\/th\u003e\n \u003cth\u003eWidth\u003c\/th\u003e\n \u003cth\u003eDepth\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eLME75.000A2 230V\u003c\/td\u003e\n \u003ctd\u003e180mm\u003c\/td\u003e\n \u003ctd\u003e120mm\u003c\/td\u003e\n \u003ctd\u003e52.6mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774259527934,"sku":"SPA635","price":351.54,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-LME75000A2-230V-Burner-Control-Box-Control-Box_e05dbbfa-84ec-4889-8d5b-23b970cec2c3.webp?v=1753853503"},{"product_id":"siemens-lme76-000a2-230v-burner-control-box","title":"Siemens LME76.000A2 230v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME76.000A2 Burner Control Box 230V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME76.000A2 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\u003cimg width=\"85%\" alt=\"LME76.000A2 In Use\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/AdobeStock_203428400.jpg?10352\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME76.000A2 Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME76 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003cbr\u003e\n \u003cp\u003eThis control box has a designed lifetime* of 250,000 burner startup cycles which, under normal operating conditions in heating mode, correspond to approx. 10 years of usage (starting from the production date given on the type field).\u003c\/p\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eFeatures\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eOutput actuator control\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n \u003cli\u003eInput feedback for actuator with a potentiometer\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg width=\"100%\" alt=\"LME76.000A2 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n \u003ctable class=\"table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Box\u003c\/th\u003e\n \u003cth\u003eHeight\u003c\/th\u003e\n \u003cth\u003eWidth\u003c\/th\u003e\n \u003cth\u003eDepth\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eLME76.000A2 230V\u003c\/td\u003e\n \u003ctd\u003e180mm\u003c\/td\u003e\n \u003ctd\u003e120mm\u003c\/td\u003e\n \u003ctd\u003e52.6mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43774259560702,"sku":"SPA634","price":376.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-LME76000A2-230V-Burner-Control-Box-Control-Box_6f65a810-0285-471d-b926-76dfb1ea1f3a.webp?v=1753853502"},{"product_id":"siemens-lme75-000a1-burner-control-basic-unit","title":"Siemens LME75.000A1 110v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-12\"\u003e\n \u003ch2\u003eSiemens LME75.000A2 Burner Control Box 230V\u003c\/h2\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003ch3\u003eOverview\u003c\/h3\u003e\n \u003cp\u003eThe \u003cspan\u003eburner control L\u003c\/span\u003eME75.000A1 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n \u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eLME75.000A1 Burner Control Box Applications\u003c\/h3\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003eThe LME75 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003cbr\u003e\n \u003cp\u003eThis control box has a designed lifetime* of 250,000 burner startup cycles which, under normal operating conditions in heating mode, correspond to approx. 10 years of usage (starting from the production date given on the type field).\u003c\/p\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-md-6\"\u003e\n \u003ch3\u003eFeatures\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eUndervoltage detection\u003c\/li\u003e\n \u003cli\u003eOutput actuator control\u003c\/li\u003e\n \u003cli\u003eSupply Voltage: 110VAC\u003c\/li\u003e\n \u003cli\u003eInput feedback for actuator with a potentiometer\u003c\/li\u003e\n \u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n \u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n \u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n \u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n \u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\" alt=\"LME75.000A2 Dimensions\" width=\"100%\"\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003chr\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-md-12\"\u003e\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n \u003ctable class=\"table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Box\u003c\/th\u003e\n \u003cth\u003eHeight\u003c\/th\u003e\n \u003cth\u003eWidth\u003c\/th\u003e\n \u003cth\u003eDepth\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eLME75.000A1 110V\u003c\/td\u003e\n \u003ctd\u003e180mm\u003c\/td\u003e\n \u003ctd\u003e120mm\u003c\/td\u003e\n \u003ctd\u003e52.6mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579623829758,"sku":"SPA1208","price":402.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/Siemens-LME76000A2-230V-Burner-Control-Box-Control-Box_a97c617c-4668-44b4-bcd1-13be7c348203.webp?v=1753852504"},{"product_id":"siemens-pme71-111a1-program-mod-f-lme71-000a1","title":"Siemens PME71.111A1 Programming Module 110v","description":"Professional PME71 series program module designed for LME71.000A1 flame safeguard controllers. Pilot or direct spark ignition with purge sequence. Key features include: Purge sequence, No actuator control, No valve proving, Pilot or direct spark. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.111A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Pilot or direct spark ignition with purge sequence\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003ePurge sequence\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003ePilot or direct spark\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME71.000A1 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579626909950,"sku":"SPA1226","price":86.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_a8c710f5-1923-4d4d-9a41-e99efdf9bec8.png?v=1753852488"},{"product_id":"siemens-pme71-111a2-program-mod-f-lme71-000a2","title":"Siemens PME71.111A2 Programming Module 230v","description":"Professional PME71 series program module designed for LME71.000A2 flame safeguard controllers. Pilot or direct spark ignition with purge sequence. Key features include: Purge sequence, No actuator control, No valve proving, Pilot or direct spark. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.111A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Pilot or direct spark ignition with purge sequence\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003ePurge sequence\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003ePilot or direct spark\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME71.000A2 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579627532542,"sku":"SPA1227","price":86.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_5e813198-c428-4727-b1e9-ca4213a1eb2f.png?v=1753852487"},{"product_id":"siemens-pme71-112a1-program-mod-f-lme71-000a1","title":"Siemens PME71.112A1 Programming Module 110v","description":"Professional PME71 series program module designed for LME71.000A1 flame safeguard controllers. Pilot or direct spark ignition without purge sequence. Key features include: No purge sequence, No actuator control, No valve proving, Pilot or direct spark. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.112A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Pilot or direct spark ignition without purge sequence\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eNo purge sequence\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003ePilot or direct spark\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME71.000A1 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579627565310,"sku":"SPA1228","price":86.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_58c4a3e5-fa80-40b3-9e9a-61557a779eaf.png?v=1753852486"},{"product_id":"siemens-pme71-112a2-program-mod-f-lme71-000a2","title":"Siemens PME71.112A2 Programming Module 230v","description":"Professional PME71 series program module designed for LME71.000A2 flame safeguard controllers. Pilot or direct spark ignition without purge sequence. Key features include: No purge sequence, No actuator control, No valve proving, Pilot or direct spark. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.112A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Pilot or direct spark ignition without purge sequence\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eNo purge sequence\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003ePilot or direct spark\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME71.000A2 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579627630846,"sku":"SPA1229","price":86.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_33965803-5050-4d95-ab62-0ed087f209b2.png?v=1753852486"},{"product_id":"siemens-pme71-401a2-program-mod-f-lme71-000a2","title":"Siemens PME71.401A2 Programming Module 230v","description":"Professional PME71 series program module designed for LME71.000A2 flame safeguard controllers. Basic flame safeguard with extended features. Key features include: Extended capability, No actuator control, Enhanced safety. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.401A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Basic flame safeguard with extended features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eExtended capability\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME71.000A2 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579627696382,"sku":"SPA1231","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_52cee14f-a79d-48a4-b6c7-5704e04345ed.png?v=1753852485"},{"product_id":"siemens-pme71-402a1-program-mod-f-lme71-000a1","title":"Siemens PME71.402A1 Programming Module 110v","description":"Professional PME71 series program module designed for LME71.000A1 flame safeguard controllers. Basic flame safeguard with extended features. Key features include: Extended capability, No actuator control, Enhanced safety. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.402A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Basic flame safeguard with extended features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eExtended capability\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME71.000A1 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579627729150,"sku":"SPA1230","price":86.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_9afc7b63-52dd-40c8-97b8-4348df90e461.png?v=1753852484"},{"product_id":"siemens-pme71-402a2-program-mod-f-lme71-000a2","title":"Siemens PME71.402A2 Programming Module 230v","description":"Professional PME71 series program module designed for LME71.000A2 flame safeguard controllers. Basic flame safeguard with extended features. Key features include: Extended capability, No actuator control, Enhanced safety. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.402A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Basic flame safeguard with extended features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eExtended capability\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME71.000A2 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579627761918,"sku":"SPA1232","price":86.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_58db2939-5f90-40c7-8261-87c12945682a.png?v=1753852483"},{"product_id":"siemens-pme71-901a1-program-mod-f-lme71-000a1","title":"Siemens PME71.901A1 Programming Module 110v","description":"Professional PME71 series program module designed for LME71.000A1 flame safeguard controllers. PWM blower control with direct spark ignition and valve proving. Key features include: PWM blower control, Direct spark only, Valve proving, No actuator control. Provides PWM blower control, valve proving. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME71.901A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME71\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME71.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e PWM blower control with direct spark ignition and valve proving\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003ePWM blower control\u003c\/li\u003e\n \u003cli\u003eDirect spark only\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eNo actuator control\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME71 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME71.000A1 \u003cbr\u003e PWM Blower Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579628384510,"sku":"SPA1235","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_499e49d8-ec77-43bc-857a-a4e857606cc8.png?v=1753852482"},{"product_id":"siemens-pme73-810a1-progr-mod-f-lme73-000a1","title":"Siemens PME73.810A1 Programming Module 110v","description":"Professional PME73 series program module designed for LME73.000A1 flame safeguard controllers. Basic actuator control with standard features. Key features include: Basic actuator control, Standard operation, POC monitoring. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.810A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Basic actuator control with standard features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eBasic actuator control\u003c\/li\u003e\n \u003cli\u003eStandard operation\u003c\/li\u003e\n \u003cli\u003ePOC monitoring\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME73.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579628417278,"sku":"SPA1233","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_a7eed29b-0d42-4343-86f1-58af53a95163.png?v=1753852481"},{"product_id":"siemens-pme73-810a2-programming-module","title":"Siemens PME73.810A2 Programming Module 230v","description":"Professional PME73 series program module designed for LME73.000A2 flame safeguard controllers. Basic actuator control with standard features. Key features include: Basic actuator control, Standard operation, POC monitoring. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.810A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Basic actuator control with standard features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eBasic actuator control\u003c\/li\u003e\n \u003cli\u003eStandard operation\u003c\/li\u003e\n \u003cli\u003ePOC monitoring\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME73.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579628646654,"sku":"SPA1234","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_93d211c4-83cc-4309-aa0a-ae9dfcc46294.png?v=1753852480"},{"product_id":"siemens-pme73-811a1-program-mod-f-lme73-000a1","title":"Siemens PME73.811A1 Programming Module 110v","description":"Professional PME73 series program module designed for LME73.000A1 flame safeguard controllers. Modulating actuator control with valve proving, ignition position equals low fire. Key features include: Modulating actuator control, Valve proving, Ignition position = low fire, POC monitoring. Provides actuator control, valve proving. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.811A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving, ignition position equals low fire\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIgnition position = low fire\u003c\/li\u003e\n \u003cli\u003ePOC monitoring\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME73.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579628679422,"sku":"SPA1236","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_8f6f472d-1823-4863-b66f-dd767e480352.png?v=1753852479"},{"product_id":"siemens-pme73-811a2-program-mod-f-lme73-000a2","title":"Siemens PME73.811A2 Programming Module 230v","description":"Professional PME73 series program module designed for LME73.000A2 flame safeguard controllers. Modulating actuator control with valve proving, ignition position equals low fire. Key features include: Modulating actuator control, Valve proving, Ignition position = low fire, POC monitoring. Provides actuator control, valve proving. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.811A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving, ignition position equals low fire\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIgnition position = low fire\u003c\/li\u003e\n \u003cli\u003ePOC monitoring\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME73.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579629236478,"sku":"SPA1237","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_87f9bc78-42ce-457a-a7d9-8759a2c25d87.png?v=1753852478"},{"product_id":"siemens-pme73-812a1-program-mod-f-lme73-000a1","title":"Siemens PME73.812A1 Programming Module 110v","description":"Professional PME73 series program module designed for LME73.000A1 flame safeguard controllers. Modulating actuator control with independent ignition position, no valve proving. Key features include: Modulating actuator control, Independent ignition position, No valve proving, SQM4 compatible. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.812A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with independent ignition position, no valve proving\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003eSQM4 compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME73.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579629269246,"sku":"SPA1238","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_a508de5a-54fb-4643-a329-4476aa97d094.png?v=1753852478"},{"product_id":"siemens-pme73-812a2-program-mod-f-lme73-000a2","title":"Siemens PME73.812A2 Programming Module 230v","description":"Professional PME73 series program module designed for LME73.000A2 flame safeguard controllers. Modulating actuator control with independent ignition position, no valve proving. Key features include: Modulating actuator control, Independent ignition position, No valve proving, SQM4 compatible. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.812A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with independent ignition position, no valve proving\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003eSQM4 compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME73.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579629302014,"sku":"SPA1239","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_e1a65b73-886f-4ec6-8d50-5b58d5ced326.png?v=1753852477"},{"product_id":"siemens-pme73-820a1-progr-mod-f-lme73-000a1","title":"Siemens PME73.820A1 Programming Module 110v","description":"Professional PME73 series program module designed for LME73.000A1 flame safeguard controllers. Enhanced actuator control with advanced features. Key features include: Enhanced actuator control, Advanced functionality, POC monitoring. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.820A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Enhanced actuator control with advanced features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eEnhanced actuator control\u003c\/li\u003e\n \u003cli\u003eAdvanced functionality\u003c\/li\u003e\n \u003cli\u003ePOC monitoring\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME73.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579629367550,"sku":"SPA1242","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_35ba052a-d1be-43f1-99a6-ccbd73646735.png?v=1753852476"},{"product_id":"siemens-pme73-820a2-programming-module","title":"Siemens PME73.820A2 Programming Module 230v","description":"Professional PME73 series program module designed for LME73.000A2 flame safeguard controllers. Enhanced actuator control with advanced features. Key features include: Enhanced actuator control, Advanced functionality, POC monitoring. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.820A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Enhanced actuator control with advanced features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eEnhanced actuator control\u003c\/li\u003e\n \u003cli\u003eAdvanced functionality\u003c\/li\u003e\n \u003cli\u003ePOC monitoring\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME73.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579629400318,"sku":"SPA1240","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_5b9dcbff-5ca1-4b69-8794-d351264b6d4b.png?v=1753852475"},{"product_id":"siemens-pme73-830a2-programming-module-f-lme73","title":"Siemens PME73.830A2 Programming Module 230v","description":"Professional PME73 series program module designed for LME73.000A2 flame safeguard controllers. Advanced actuator control with enhanced safety features. Key features include: Advanced actuator control, Enhanced safety, Multiple operating modes. Provides actuator control. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.830A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced actuator control with enhanced safety features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced actuator control\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003cli\u003eMultiple operating modes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME73.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579629727998,"sku":"SPA1241","price":106.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_6b0d6f14-0858-4662-bad9-15befd32b1b0.png?v=1753852473"},{"product_id":"siemens-pme73-831a1-programming-module-f-lme","title":"Siemens PME73.831A1 Programming Module 110v","description":"Professional PME73 series program module designed for LME73.000A1 flame safeguard controllers. Modulating actuator control with valve proving and independent ignition position, no POC. Key features include: Modulating actuator control, Valve proving, Independent ignition position, No POC. Provides actuator control, valve proving. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.831A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving and independent ignition position, no POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eNo POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME73.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630022910,"sku":"SPA1243","price":113.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_af9a5fa7-494b-4d1f-bc62-594dcd2cd8d5.png?v=1753852472"},{"product_id":"siemens-pme73-831a2-programming-module-f-lme73","title":"Siemens PME73.831A2 Programming Module 230v","description":"Professional PME73 series program module designed for LME73.000A2 flame safeguard controllers. Modulating actuator control with valve proving and independent ignition position, no POC. Key features include: Modulating actuator control, Valve proving, Independent ignition position, No POC. Provides actuator control, valve proving. Compatible with flame rods and UV scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME73.831A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME73\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME73.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving and independent ignition position, no POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eNo POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME73 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME73.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, UV Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630055678,"sku":"SPA1244","price":106.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_0efda31e-4e19-4289-908b-06c987ddbeec.png?v=1753852470"},{"product_id":"siemens-pme75-231a1-program-for-lme75-000a1","title":"Siemens PME75.231A1 Programming Module 110v","description":"Professional PME75 series program module designed for LME75.000A1 flame safeguard controllers. Basic self-check scanner capability with essential features. Key features include: Self-check scanner capability, Basic functionality, Enhanced safety. Provides self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.231A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Basic self-check scanner capability with essential features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eSelf-check scanner capability\u003c\/li\u003e\n \u003cli\u003eBasic functionality\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME75.000A1 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630088446,"sku":"SPA1245","price":122.43,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_a15b15b4-9f34-4d0e-84a8-63fa1092502e.png?v=1753852469"},{"product_id":"siemens-pme75-231a2-program-for-lme75-000a2","title":"Siemens PME75.231A2 Programming Module 230v","description":"\u003cp\u003eProfessional PME75 series program module designed for LME75.000A2 flame safeguard controllers. Basic self-check scanner capability with essential features. Key features include: Self-check scanner capability, Basic functionality, Enhanced safety. Provides self-check scanner capability. Compatible with flame rods and self-checking scanners.\u003c\/p\u003e\n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.231A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Basic self-check scanner capability with essential features\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eSelf-check scanner capability\u003c\/li\u003e\n \u003cli\u003eBasic functionality\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003eVoltage: 230V \u003cbr\u003eCompatible Base Unit: LME75.000A2 \u003cbr\u003eProof of Closure: Yes \u003cbr\u003eFlame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630153982,"sku":"SPA1246","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_884d34a4-1200-491f-81a9-60121fdd428b.png?v=1753852468"},{"product_id":"siemens-pme75-811a1-program-for-lme75-000a1","title":"Siemens PME75.811A1 Programming Module 110v","description":"Professional PME75 series program module designed for LME75.000A1 flame safeguard controllers. Modulating actuator control with valve proving, self-check scanner or flame rod, ignition position equals low fire. Key features include: Modulating actuator control, Valve proving, Self-check scanner capability, Ignition = low fire. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.811A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving, self-check scanner or flame rod, ignition position equals low fire\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner capability\u003c\/li\u003e\n \u003cli\u003eIgnition = low fire\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME75.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630186750,"sku":"SPA1247","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens.png?v=1753852466"},{"product_id":"siemens-pme75-811a2-program-for-lme75-000a2","title":"Siemens PME75.811A2 Programming Module 230v","description":"Professional PME75 series program module designed for LME75.000A2 flame safeguard controllers. Modulating actuator control with valve proving, self-check scanner or flame rod, ignition position equals low fire. Key features include: Modulating actuator control, Valve proving, Self-check scanner capability, Ignition = low fire. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.811A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving, self-check scanner or flame rod, ignition position equals low fire\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner capability\u003c\/li\u003e\n \u003cli\u003eIgnition = low fire\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME75.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630252286,"sku":"SPA1248","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_4738643a-922c-4ee9-b212-e021f3c2ca76.png?v=1753852466"},{"product_id":"siemens-pme75-812a1-program-for-lme75-000a1","title":"Siemens PME75.812A1 Programming Module 110v","description":"Professional PME75 series program module designed for LME75.000A1 flame safeguard controllers. Modulating actuator control with independent ignition position, no valve proving, self-check scanner or flame rod. Key features include: Modulating actuator control, Independent ignition position, No valve proving, Self-check scanner. Provides actuator control, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.812A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with independent ignition position, no valve proving, self-check scanner or flame rod\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME75.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630809342,"sku":"SPA1250","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_8164f4d4-22c7-4fdb-9c69-3efb0240ef9c.png?v=1753852465"},{"product_id":"siemens-pme75-812a2-program-for-lme75-000a2","title":"Siemens PME75.812A2 Programming Module 230v","description":"Professional PME75 series program module designed for LME75.000A2 flame safeguard controllers. Modulating actuator control with independent ignition position, no valve proving, self-check scanner or flame rod. Key features include: Modulating actuator control, Independent ignition position, No valve proving, Self-check scanner. Provides actuator control, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.812A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with independent ignition position, no valve proving, self-check scanner or flame rod\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME75.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630842110,"sku":"SPA1249","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_30aae020-d3d5-4056-a955-748f93de169d.png?v=1753852464"},{"product_id":"siemens-pme75-831a1-program-for-lme75-000a1","title":"Siemens PME75.831A1 Programming Module 110v","description":"Professional PME75 series program module designed for LME75.000A1 flame safeguard controllers. Modulating actuator control with valve proving and independent ignition position, self-check scanner or flame rod, no POC. Key features include: Modulating actuator control, Valve proving, Independent ignition position, Self-check scanner, No POC. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.831A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving and independent ignition position, self-check scanner or flame rod, no POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003cli\u003eNo POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME75.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630874878,"sku":"SPA1251","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_4665d0e1-dd71-4649-a487-92af74f89b98.png?v=1753852463"},{"product_id":"siemens-pme75-831a2-program-for-lme75-000a2","title":"Siemens PME75.831A2 Programming Module 230v","description":"Professional PME75 series program module designed for LME75.000A2 flame safeguard controllers. Modulating actuator control with valve proving and independent ignition position, self-check scanner or flame rod, no POC. Key features include: Modulating actuator control, Valve proving, Independent ignition position, Self-check scanner, No POC. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME75.831A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME75\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME75.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Modulating actuator control with valve proving and independent ignition position, self-check scanner or flame rod, no POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eModulating actuator control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003cli\u003eNo POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME75 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME75.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630940414,"sku":"SPA1252","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_038fb717-e6b8-47ba-bcaf-446c5e6d731e.png?v=1753852462"},{"product_id":"siemens-pme76-231a2-program-for-lme76-000a2","title":"Siemens PME76.231A2 Programming Module 230v","description":"Professional PME76 series program module designed for LME76.000A2 flame safeguard controllers. Advanced self-check scanner capability with enhanced features. Key features include: Advanced self-check scanner, Enhanced functionality, Superior safety. Provides self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME76.231A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME76\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME76.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced self-check scanner capability with enhanced features\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced self-check scanner\u003c\/li\u003e\n \u003cli\u003eEnhanced functionality\u003c\/li\u003e\n \u003cli\u003eSuperior safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME76 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME76.000A2 \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579630973182,"sku":"SPA1253","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_f43893f5-952f-4ee1-899e-fe97cba3f50e.png?v=1753852461"},{"product_id":"siemens-pme76-811a1-program-for-lme76-000a1","title":"Siemens PME76.811A1 Programming Module 110v","description":"Professional PME76 series program module designed for LME76.000A1 flame safeguard controllers. Advanced modulating actuator control with valve proving and self-check scanner capability. Key features include: Advanced modulating control, Valve proving, Self-check scanner, Enhanced safety. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME76.811A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME76\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME76.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced modulating actuator control with valve proving and self-check scanner capability\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced modulating control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME76 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME76.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579631333630,"sku":"SPA1254","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_49f46424-e7ab-41fb-8fbf-389c45fa5677.png?v=1753852461"},{"product_id":"siemens-pme76-811a2-program-for-lme76-000a2","title":"Siemens PME76.811A2 Programming Module 230v","description":"Professional PME76 series program module designed for LME76.000A2 flame safeguard controllers. Advanced modulating actuator control with valve proving and self-check scanner capability. Key features include: Advanced modulating control, Valve proving, Self-check scanner, Enhanced safety. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME76.811A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME76\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME76.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced modulating actuator control with valve proving and self-check scanner capability\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced modulating control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003cli\u003eEnhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME76 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME76.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579631595774,"sku":"SPA1255","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_c3cafc8f-4290-41c2-8796-0b52fb22c316.png?v=1753852460"},{"product_id":"siemens-pme76-812a2-program-for-lme76-000a2","title":"Siemens PME76.812A2 Programming Module 230v","description":"Professional PME76 series program module designed for LME76.000A2 flame safeguard controllers. Advanced modulating actuator control with independent ignition position and self-check scanner. Key features include: Advanced modulating control, Independent ignition position, Self-check scanner, No valve proving. Provides actuator control, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME76.812A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME76\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME76.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced modulating actuator control with independent ignition position and self-check scanner\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced modulating control\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003cli\u003eNo valve proving\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME76 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME76.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Proof of Closure: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579632611582,"sku":"SPA1256","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_93c33738-74ed-4ee7-9c1c-f9c69f5c5785.png?v=1753852459"},{"product_id":"siemens-pme76-831a1-program-for-lme76-000a1","title":"Siemens PME76.831A1 Programming Module 110v","description":"Professional PME76 series program module designed for LME76.000A1 flame safeguard controllers. Advanced modulating actuator control with valve proving, independent ignition position, and self-check scanner, no POC. Key features include: Advanced modulating control, Valve proving, Independent ignition position, Self-check scanner, No POC. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME76.831A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME76\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 110V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME76.000A1\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced modulating actuator control with valve proving, independent ignition position, and self-check scanner, no POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced modulating control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003cli\u003eNo POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME76 \u003cbr\u003e Voltage: 110V \u003cbr\u003e Compatible Base Unit: LME76.000A1 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579632742654,"sku":"SPA1257","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_6ac66ecf-a087-46d2-af92-38fdec62ff4f.png?v=1753852458"},{"product_id":"siemens-pme76-831a2-program-for-lme76-000a2","title":"Siemens PME76.831A2 Programming Module 230v","description":"Professional PME76 series program module designed for LME76.000A2 flame safeguard controllers. Advanced modulating actuator control with valve proving, independent ignition position, and self-check scanner, no POC. Key features include: Advanced modulating control, Valve proving, Independent ignition position, Self-check scanner, No POC. Provides actuator control, valve proving, self-check scanner capability. Compatible with flame rods and self-checking scanners.\n \n \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eModel:\u003c\/strong\u003e PME76.831A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSeries:\u003c\/strong\u003e PME76\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eCompatible Base Unit:\u003c\/strong\u003e LME76.000A2\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Advanced modulating actuator control with valve proving, independent ignition position, and self-check scanner, no POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eCapabilities \u0026amp; Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eActuator Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePWM Blower Control:\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eValve Proving:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eProof of Closure (POC):\u003c\/strong\u003e No\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eAnalog Input:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eIndependent Ignition Position:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003ePurge Independent:\u003c\/strong\u003e Yes\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eFlame Detection Compatibility\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003e\n \u003cstrong\u003eFlame Rod:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eNon-Self-Checking UV Scanner:\u003c\/strong\u003e Not Compatible\u003c\/li\u003e\n \u003cli\u003e\n \u003cstrong\u003eSelf-Checking Scanner:\u003c\/strong\u003e Compatible\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eKey Features\u003c\/h3\u003e\n \u003cul\u003e\n \u003cli\u003eAdvanced modulating control\u003c\/li\u003e\n \u003cli\u003eValve proving\u003c\/li\u003e\n \u003cli\u003eIndependent ignition position\u003c\/li\u003e\n \u003cli\u003eSelf-check scanner\u003c\/li\u003e\n \u003cli\u003eNo POC\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eBurner Specifications\u003c\/h3\u003e\n \u003cp\u003eSeries: PME76 \u003cbr\u003e Voltage: 230V \u003cbr\u003e Compatible Base Unit: LME76.000A2 \u003cbr\u003e Actuator Control: Yes \u003cbr\u003e Valve Proving: Yes \u003cbr\u003e Analog Input: Yes \u003cbr\u003e Independent Ignition Position: Yes \u003cbr\u003e Flame Detection: Flame Rod, Self-Check Scanner\u003c\/p\u003e\n \n \u003ch3\u003eApplications\u003c\/h3\u003e\n \u003cp\u003eIdeal for industrial thermal process applications requiring:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eReliable flame safeguard control\u003c\/li\u003e\n \u003cli\u003eIndustrial heating equipment management\u003c\/li\u003e\n \u003cli\u003eBurner safety and automation systems\u003c\/li\u003e\n \u003cli\u003eProcess heating control solutions\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003ch3\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n \u003cp\u003eEngineered to meet industrial safety standards with comprehensive safety interlocks and programmable operation parameters. Suitable for demanding industrial applications requiring precise flame management and safety compliance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44579632972030,"sku":"SPA1258","price":139.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/files\/pme75.811a1-siemens_747efd89-dca1-4e0a-8117-40637627feca.png?v=1753853800"},{"product_id":"siemens-azl52-00b1-display-unit","title":"Siemens AZL52.00B1 Display Unit","description":"\u003ch2 data-section-id=\"fmppqx\" data-start=\"84\" data-end=\"164\"\u003eSiemens AZL52.00B1 Display Unit – Burner Control Interface \u0026amp; Diagnostics Tool\u003c\/h2\u003e\n\u003cp data-start=\"166\" data-end=\"570\"\u003eThe \u003cstrong data-start=\"170\" data-end=\"205\"\u003eSiemens AZL52.00B1 Display Unit\u003c\/strong\u003e is a dedicated \u003cstrong data-start=\"221\" data-end=\"264\"\u003eoperating and diagnostic display module\u003c\/strong\u003e designed for use with Siemens burner management systems, including the LMV and LME series controllers. This compact and user-friendly interface provides real-time access to burner status, fault diagnostics, and parameter settings, making it an essential tool for commissioning, servicing, and maintenance.\u003c\/p\u003e\n\u003chr data-start=\"572\" data-end=\"575\"\u003e\n\u003ch3 data-section-id=\"1efomr0\" data-start=\"577\" data-end=\"596\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"598\" data-end=\"1098\"\u003e\n\u003cli data-section-id=\"3ni970\" data-start=\"598\" data-end=\"700\"\u003e\n\u003cstrong data-start=\"600\" data-end=\"621\"\u003eClear LCD Display\u003c\/strong\u003e\u003cbr data-start=\"621\" data-end=\"624\"\u003eEasy-to-read interface for monitoring burner operation and system status\u003c\/li\u003e\n\u003cli data-section-id=\"er8h0o\" data-start=\"702\" data-end=\"814\"\u003e\n\u003cstrong data-start=\"704\" data-end=\"734\"\u003eFull Diagnostic Capability\u003c\/strong\u003e\u003cbr data-start=\"734\" data-end=\"737\"\u003eEnables quick identification of faults and error codes, reducing downtime\u003c\/li\u003e\n\u003cli data-section-id=\"16tukou\" data-start=\"816\" data-end=\"917\"\u003e\n\u003cstrong data-start=\"818\" data-end=\"842\"\u003eParameter Adjustment\u003c\/strong\u003e\u003cbr data-start=\"842\" data-end=\"845\"\u003eAllows engineers to configure and fine-tune burner settings directly\u003c\/li\u003e\n\u003cli data-section-id=\"vr9q1t\" data-start=\"919\" data-end=\"1013\"\u003e\n\u003cstrong data-start=\"921\" data-end=\"951\"\u003ePlug-and-Play Connectivity\u003c\/strong\u003e\u003cbr data-start=\"951\" data-end=\"954\"\u003eSimple connection to compatible Siemens burner controls\u003c\/li\u003e\n\u003cli data-section-id=\"dl9vid\" data-start=\"1015\" data-end=\"1098\"\u003e\n\u003cstrong data-start=\"1017\" data-end=\"1046\"\u003eCompact \u0026amp; Portable Design\u003c\/strong\u003e\u003cbr data-start=\"1046\" data-end=\"1049\"\u003eIdeal for on-site commissioning and servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1100\" data-end=\"1103\"\u003e\n\u003ch3 data-section-id=\"8s7q2m\" data-start=\"1105\" data-end=\"1125\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp data-start=\"1127\" data-end=\"1164\"\u003eThe AZL52.00B1 is commonly used with:\u003c\/p\u003e\n\u003cul data-start=\"1165\" data-end=\"1273\"\u003e\n\u003cli data-section-id=\"1wbfhrg\" data-start=\"1165\" data-end=\"1206\"\u003eSiemens LMV burner management systems\u003c\/li\u003e\n\u003cli data-section-id=\"13tbeqq\" data-start=\"1207\" data-end=\"1236\"\u003eSiemens LME control boxes\u003c\/li\u003e\n\u003cli data-section-id=\"hswwgo\" data-start=\"1237\" data-end=\"1273\"\u003eCompatible OCI interface systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1275\" data-end=\"1278\"\u003e\n\u003ch3 data-section-id=\"nez4hq\" data-start=\"1280\" data-end=\"1299\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1301\" data-end=\"1462\"\u003e\n\u003cli data-section-id=\"1w5eq6v\" data-start=\"1301\" data-end=\"1338\"\u003eIndustrial and commercial burners\u003c\/li\u003e\n\u003cli data-section-id=\"1befdg3\" data-start=\"1339\" data-end=\"1373\"\u003eGas and oil combustion systems\u003c\/li\u003e\n\u003cli data-section-id=\"zwtf1i\" data-start=\"1374\" data-end=\"1417\"\u003eBoiler and process heating applications\u003c\/li\u003e\n\u003cli data-section-id=\"181oo5s\" data-start=\"1418\" data-end=\"1462\"\u003eCommissioning and servicing environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":57201174315390,"sku":"SPA2438","price":555.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/products\/Siemens-AZL52-Operator-Display-For-LMV5-Display-Unit_5dd5aa38-7e26-4a73-8954-f2565814d5f6.webp?v=1753853671"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/4028\/9022\/collections\/Siemens_LME7.png?v=1701253044","url":"https:\/\/comtherm-shop.myshopify.com\/collections\/siemens-lme-controls.oembed?page=3","provider":"Comtherm Ltd","version":"1.0","type":"link"}